Lutron CO2-9914SD CO2 Meter | SD Card

SKU
CO2-9914SD
฿25,900.00
In stock

5 in 1 Portable CO2  Meter
Measured CO| Temp. | Humidity | Dew Point | Wet bulb
Supplied CO2 Probe, Humidity probe | range: 0 to 10,000 ppm
Data storage via SD Memory Card (2 GB to 16 GB.)
Data hold, Record (Max., Min.) and Auto Power Off
LCD display with green Backlight easy to readout
RS232/USB computer interface.
Lutron

Add to Compare

Lutron CO2-9914SD CO2 Meter | SD Card

CO2 Meter supplied with CO2 probe, Humidity probe, Probe size: ø28 mm, wide measurement range: 0 to 10,000 ppm. Fast responding and High accuracy. LCD display with green backlight easy to read even in the dark environment. Data hold, Record (Max., Min.) and Auto Power Off. Data output to COMPUTER with RS232, USB PC interface (optional)

Convenient with 5 in 1 Measurement

  • CO2
  • Temperature
  • Humidity
  • Dew point
  • Wet bulb

Data logger with both Auto & Manual on SD Memory Card (1 to 16 GB). Display the data as "Excel file", Just put SD Card into computer. Sampling Time can be setting from 1 to 3600 seconds, built-in clock and calendar show in data value.

EXCEL data screen (for example) EXCEL graphic screen (for example)
EXCEL data screen (for example) EXCEL graphic screen (for example)

▼ CO2 (Carbon Dioxide)

Measurement Range Resolution Accuracy
CO2 (Carbon Dioxide) 0 to 10,000 ppm 1 ppm ± 40 ppm (≤ 1,000 ppm)
± (50 ppm + 3% of rdg)
   (> 1,000 ppm, ≤ 3,000 ppm)
± (50 ppm + 5% of rdg)
   (> 3,000 ppm, reference only)

 Temperature

Measurement Range Resolution Accuracy
Temperature 0 to 50℃ 0.1℃ ±0.8℃

 Humidity

Measurement Range Resolution Accuracy
Humidity 5 to 95% RH 0.1% RH ± 3% RH (< 70% RH)
± (3% reading + 1% RH)

 Dew Point

Measurement Range Resolution Remark
Dew Point -25.3 to 48.9℃ 0.1℃ Dew Point display value is calculated from the Humidity, Temp. measurement automatically.

 Wet bulb

Measurement Range Resolution Accuracy
Wet bulb -21.6 to 50.0℃ 0.1℃ Wet bulb display value is calculated from the Humidity, Temp. measurement automatically.
Display LCD size : 52 mm x 38 mm
LCD with green backlight (ON/ OFF)
Sensor structure CO NDIR *Nondispersive infrared sensor
Humidity Precision capacitance sensor
Temperature Precision thermistor
Circuit Custom one-chip of microprocessor LSI circuit.
Datalogger Sampling Time
Setting range
Auto 2 second to 3600 seconds
(Sampling time can set to 1 second, but memory data may loss)
Manual Push the data logger button once will save data one time
(Set the sampling time to 0 second.)
(Manual mode, can also select the 1 to 99 position ( Location ) no.)
Memory Card SD memory card. 1 GB to 16 GB.
Advanced
  • Set clock time
  • Set sampling time
  • Auto power OFF management
  • Set beep Sound ON/OFF
  • Decimal point of SD card setting
  • SD memory card Format
  • Temp. unit setting
  • Alarm value setting
  • Altitude value setting
Data Output RS232/USB PC computer interface
  • Connect the optional RS232 cable UPCB-02 will get the RS232 plug
  • Connect the optional USB cable USB-01 will get the USB plug.
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value
Sampling Time of Display Approx. 1 second.
Power Requirement Battery AA × 6 or Adapter ADC 9V (optional)
Dimension (Weight)
  • Main Unit: 177 x 68 x 45 mm (350 g)
  • CO2, Humidity probe: ø28 x 175 mm
SKUCO2-9914SD
Weight350.000000
Dimension177 x 68 x 45mm
ManufacturerLutron
Data loggerYes
Monitoring GasCO2
Resolution

CO2 (Carbon dioxide): 1 ppm
Temperature: 0.1℃
Humidity: 0.1 %RH
Dew Point Temp.: 0.1℃
Wet bulb Temp.: 0.1℃

Measurement Range

CO2 (Carbon dioxide): 0 to 10000 ppm
Temperature: 0 to 50℃
Humidity: 5 to 95 %RH
Dew Point Temp.: -25.3 to 48.9℃
Wet bulb Temp.: -21.6 to 50.0℃

Other Function
  • SD memory card Format
  • Set clock time
  • Set sampling time
  • Auto power OFF management
  • Set beep Sound ON/OFF
  • Decimal point of SD card setting
  • Temp. unit setting
  • Alarm value setting
  • Altitude value setting
Power Supply

Battery AA x 6

Water resistance

No

Sensor Output InterfaceNo
Accuracy

CO2 (Carbon dioxide): ± 40 ppm (≤ 1,000 ppm), ± (50 ppm + 3% of rdg) (> 1,000 ppm, ≤ 3,000 ppm), ± (50 ppm + 5% of rdg) (> 3,000 ppm, reference only)
Temperature: ±0.8℃
Humidity: ± 3% RH (< 70% RH), ± (3% reading + 1% RH)

Your Rating

Product's Video

แนะนำ Lutron CO2-9914SD เครื่องวัดคาร์บอนไดออกไซด์ 5 in 1 | CO2, อุณหภูมิ, ความชื้น, Dew Point, Wet bulb

ก๊าซคาร์บอนไดออกไซด์(CO2) ที่ถูกปล่อยจากการหายใจ การย่อยสลาย การเผาไหม้จากเครื่องยนต์ และโรงงานอุตสาหกรรมล้วนส่งผลต่อการใช้ชีวิต เพื่อให้คุณภาพอากาศเป็นไปตามมาตรฐาน จึงมีการคิดค้นเครื่องวัดอุณหภูมิอากาศในการตรวจสอบ ที่มีคุณลักษณะวัดค่าได้อย่างรวดเร็วและแม่นยำ

การถ่ายเทของอากาศลดความเสี่ยงในการติดเชื้อโควิด-19 ได้หรือไม่?

คาร์บอนไดออกไซด์เป็นองค์ประกอบตามธรรมชาติในอากาศ นอกจากนั้นยังเป็นลมหายใจของพันธุ์พืช และต้นไม้นานาชนิด คอยป้อนออกซิเจนให้กับมนุษย์และรับคาร์บอนไดออกไซด์จากมนุษย์ ซึ่งเป็นอย่างนี้ซ้ำไปซ้ำมา แต่รู้มั้ยว่า? คาร์บอนไดออกไซด์ (CO2) ภายในอาคาร

อุปกรณ์ที่มีมาในชุด

  • Main unit × 1
  • CO2, Humidity probe × 1
  • Instruction manual × 1
  • Hard carrying case × 1
  • Calibration Certificate (from manufacture) × 1
  • SD Card ขนาด 32GB (ทางเลกะแถมให้ฟรี) × 1
  • Batteries AA (ทางเลกะแถมให้ฟรี) × 6

อุปกรณ์เสริม (แยกจำหน่าย)