CAMPBELL CR800 Measurement and Control Datalogger

SKU
CR800
฿67,000.00
Pre-Order Item
Out of stock

Measurement and Control Datalogger
Ideal various applications
Ports CS I/O, RS-232
Maximum Scan Rate: 100Hz
Simpler in design, easier to program and wire.

Add to Compare

CAMPBELL CR800 Measurement and Control Datalogger

The CR800 is a smaller, research-grade datalogger designed for stand-alone operation in harsh, remote environments. It is intended for smaller configurations in which fewer sensors will be measured. Each CR800 reads input from sensors, then transmits the data via a communication peripheral; most sensors and telecommunication devices are compatible. Multiple CR800s can be configured as a network or units can be deployed individually.

The CR800 consists of measurement electronics encased in a plastic shell and an integrated wiring panel. This datalogger uses an external keyboard/display and power supply. Low power consumption allows the CR800 to operate for extended periods on a battery recharged with a solar panel—eliminating the need for AC power. The CR800 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.

  • Sensors
    With several channel types, the CR800 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors. A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR850's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices.
  • Measurement & Control Peripherals
    The CR800 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays.
  • Communications
    The CR800 communicates with a PC via direct connect, NL201 Ethernet Interface, multidrop modems, short haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos and High Data Rate GOES).
  • Meteorology
    The CR800 is used in long-term climatological monitoring, meteorological research, and routine weather measurement applications.
  • Wind Profiling
    Our data acquisition systems can monitor conditions at wind assessment sites, at producing wind farms, and along transmission lines.
  • Air Quality
    The CR800 can monitor and control gas analyzers, particle samplers, and visibility sensors.  The datalogger can also automatically control calibration sequences and compute conditional averages that exclude invalid data
  • Water Resources/Aquaculture
    Our CR800 is well-suited to remote, unattended monitoring of hydrologic conditions.  Most hydrologic sensors, including SDI-12 probes, interface directly to the datalogger.
  • Vehicle Testing
    This versatile, rugged datalogger is ideally suited for testing cold and hot temperature, high altitude, off-highway, and cross-country performance.
  • Soil Moisture
    The CR800 is compatible with the following soil moisture measurement technologies: Soil moisture blocks, Matric water potential sensors, TDR, Self-contained water content reflectometers and Tensiometers.
Maximum Scan Rate 100Hz
Analog Inputs 6 Single-ended or 3 differential (individually configured)
Pulse Counters 2
Switched Excitation Channels 2 voltage
Digital Ports Certain digital ports can be used to count switch closures.
4 I/Os or 2 RS-232 COM I/O ports can be paired as transmit and receive for measuring smart serial sensors.
Communications Ports 1 CS I/O
1 RS-232
Switched 12 Volt 1
Input Voltage Range ±5 Vdc
Analog Voltage Accuracy ± (0.06% of reading + offset) at 0° to 40°C
Analog Resolution 0.33 μV
A/D Bits 13
Power Requirements 9.6 to 16 Vdc
RTC Clock Accuracy ±3min. per year (Correction via GPS optional.)
Protocols Supported PakBus, Modbus, DNP3, FTP, HTTP, XML POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM
CE Compliance Standards to which Conformity is Declared IEC61326:2002
Temperature Range
Standard -25° to 50°C
Extended -55° to 85°C
Memory
Operating System 2 MB flash
CPU Usage, Program Storage & Data Storage 4 MB
Current Drain
Sleep Mode 0.7 mA (typical)
0.9 mA (max)
Active 1 to 16 mA typical (without RS-232 communication)
17 to 28 mA typical (with RS-232 communication)
Dimensions 24.1 × 10.4 × 5.1 cm
Weight 0.7kg

CAMPBELL CR850 Measurement and Control Datalogger

The CR850 is a smaller, research-grade datalogger that includes an on-board keyboard display as part of its integrated package. It is intended for smaller configurations in which fewer sensors will be measured. Each CR850 reads input from sensors, then transmits the data via a communication peripheral; most sensors and telecommunication devices are compatible. Multiple CR850s can be configured as a network or units can be deployed individually. This rugged datalogger can provide stand-alone operation in harsh, remote environments.

The CR850 consists of measurement electronics encased in a plastic shell with an integrated wiring panel, 16- character keyboard, and display screen. The display can show 8 lines x 21 characters (64 x 128 pixels). Custom menus are supported allowing customers to set up choices within the datalogger program that can be initiated by a simple “toggle” or “pick list”. Its keyboard and display screen is used to program the datalogger, manually initiate data transfer, and display data.
The CR850 uses an external  power supply. Low power consumption allows the it to operate for extended periods on a battery recharged with a solar panel—eliminating the need for AC power. The CR850 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.

  • Sensors
    With several channel types, the CR850 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors. A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR850's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices.
  • Measurement & Control Peripherals
    The CR850 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays.
  • Communications
    The CR850 communicates with a PC via direct connect, NL201 Ethernet Interface, multidrop modems, short haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos and High Data Rate GOES).
  • Meteorology
    The CR850 is used in long-term climatological monitoring, meteorological research, and routine weather measurement applications.
  • Wind Profiling
    Our data acquisition systems can monitor conditions at wind assessment sites, at producing wind farms, and along transmission lines.
  • Air Quality
    The CR850 can monitor and control gas analyzers, particle samplers, and visibility sensors.  The datalogger can also automatically control calibration sequences and compute conditional averages that exclude invalid data
  • Water Resources/Aquaculture
    Our CR850 is well-suited to remote, unattended monitoring of hydrologic conditions.  Most hydrologic sensors, including SDI-12 probes, interface directly to the datalogger.
  • Vehicle Testing
    This versatile, rugged datalogger is ideally suited for testing cold and hot temperature, high altitude, off-highway, and cross-country performance.
  • Soil Moisture
    The CR800 and CR850 are compatible with the following soil moisture measurement technologies: Soil moisture blocks, Matric water potential sensors, TDR, Self-contained water content reflectometers and Tensiometers.
Maximum Scan Rate 100Hz
Analog Inputs 6 Single-ended or 3 differential (individually configured)
Pulse Counters 2
Switched Excitation Channels 2 voltage
Digital Ports Certain digital ports can be used to count switch closures.
4 I/Os or 2 RS-232 COM I/O ports can be paired as transmit and receive for measuring smart serial sensors.
Communications Ports 1 CS I/O
1 RS-232
Switched 12 Volt 1
Input Voltage Range ±5 Vdc
Analog Voltage Accuracy ± (0.06% of reading + offset) at 0° to 40°C
Analog Resolution 0.33 μV
A/D Bits 13
Power Requirements 9.6 to 16 Vdc
RTC Clock Accuracy ±3min. per year (Correction via GPS optional.)
Protocols Supported PakBus, Modbus, DNP3, FTP, HTTP, XML POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM
CE Compliance Standards to which Conformity is Declared IEC61326:2002
Temperature Range
Standard -25° to 50°C
Extended -55° to 85°C
Memory
Operating System 2 MB flash
CPU Usage, Program Storage & Data Storage 4 MB
Current Drain
Sleep Mode 0.7 mA (typical)
0.9 mA (max)
Active 1 to 16 mA typical (without RS-232 communication)
17 to 28 mA typical (with RS-232 communication)
Dimensions 24.1 × 10.4 × 5.1 cm
Weight 0.7kg
SKUCR800
Weight700.000000
Dimension24.1 x 10.4 x 5.1 cm
Manufacturercampbell
Your Rating