Hioki-CT6590 SENSOR UNIT

SKU
CT6590
฿8,200.00
In stock

- Used to connect a CT9691, CT9692, or CT9693 Clamp-on AC/DC Sensor
- Which can be a PW3198 Power Quality Analyzer, Memory HiCorder, oscilloscope, or other device.
- Current is measured with the clamp sensor, which converts the reading and outputs it as a voltage signal.
- Continuous operating time 25 hours while connected to CT9691 to CT9693
- POWER LED display

Hioki CT6590 SENSOR UNIT

The CT6590 Sensor Unit is used to connect a CT9691, CT9692, or CT9693 Clamp-on AC/DC Sensor to a measuring
instrument, which may be a PW3198 Power Quality Analyzer, Memory HiCorder, oscilloscope, or other device.
Current is measured with the clamp sensor, which converts the reading and outputs it as a voltage signal.

Name of Parts

Specifications

General Specifications
Compatible sensors CT9691, CT9692, CT9693 Clamp on AC/DC Sensor
Clamp sensor output ranges Switchable between 2 ranges 
Accuracy guarantee for temperature and humidity 23°C ± 5°C, 80%RH or less
Amplitude accuracy ± 0.5% rdg. ± 0.5 mV
Phase accuracy ± 0.2 deg. 
Operating
temperature and
humidity range
-10°C to 40°C (14°F to 104°F), 80%RH or less
40°C to 45°C (104°F to 113°F), 60%RH or less
45°C to 50°C (113°F to 122°F), 50%RH or less
Storage temperature range -20°C to 60°C (-4°F to 140°F), 80%RH or less 
Location for use Indoor, pollution degree 2, altitude up to 2000 m
Power supply Two LR06 alkaline batteries, optional AC adapter, or 5 V to 15 VDC external power
Rated power supply voltage When using batteries: 1.5 V DC × 2
When using AC adapter or external DC power supply: 5 V to 15 V DC
Maximum rated  power When using batteries: 1 VA
When using AC adapter or external DC power supply: 1.5VA 
Continuous operating  time (Battery) Approx. 25 hours (23°C, continuous use while connected to CT9691 to CT9693) 
Output Impedance  50 Ω (±5%) 
Output cable length Approx. 1000 mm
Dimensions Approx. 36W×120H×34D mm 
Mass Approx. 165 g

 

Clamp Sensor Combination Specifications

  CT9691 CT9692 CT9693
H Range (f.s.) 100A 200A 2000A
Output rate 1mV/A 1mV/A 0.1mV/A
L Range (f.s.) 10A 20A 200A
Output rate 10mV/A 10mV/A 1mV/A
Output (f.s.) 100 mV 200 mV 200 mV

 

Accuracy

CT9691 sensor
Frequency DC DC < f ≤ 66 (Hz) 66 < f ≤ 500 (Hz)
Continuous input I ≤ 80 (A) ±1.5%rdg.
±1%f.s.
±1.5%rdg.
±1%f.s.
±2.5%rdg. / ±1%f.s.
80 < I ≤ 100 (A) ±3.0%rdg. / ±1%f.s.
Phase - ±2deg. Not defined.
CT9692 sensor
Frequency DC DC < f ≤ 66 (Hz) 66 < f ≤ 500 (Hz)
Continuous input I ≤ 200 (A) ±1.5%rdg. / ±0.5%f.s. ±1.5%rdg. / ±0.5%f.s. ±2.5%rdg. / ±0.5%f.s.
Phase - ±2deg. Not defined.
CT9693 sensor
Frequency DC 45 < f ≤ 66 (Hz) DC < f ≤ 45, 66 < f ≤ 1k (Hz)
Continuous input I ≤ 1800 (A) ±2.0%rdg.
±0.5%f.s.
±1.5%rdg. / ±0.5%f.s. ±2.5%rdg. / ±0.5%f.s.
1800 < I ≤ 2000 (A) ±2.5%rdg. / ±0.5%f.s. Not defined.
Phase - ±2deg. DC < f < 45 Hz: ±2deg.
66 < f ≤ 1k (Hz): Not defined.
SKUCT6590
Weight165.000000
Dimension36 x 120 x 34 mm
ManufacturerHioki
Your Rating

Accessories Include

  • LR06 alkaline batteries x2
  • Instruction manuals x1
  • Connector cover x1

Optional Accessories

  • 9445-02 AC Adapter
  • 9445-03 AC Adapter