Fluke 1551A-12 Calibration Stik Thermometer

SKU
FLUKE-1551A-12
฿38,700.00
Pre-Order Item
Out of stock

Calibration Stik Thermometer
Accuracy of ±0.05°C over full range
Probe length 305mm (12 inches)
Minimum immersion depth 70mm
The large backlit LCD display rotates 90°
NVLAP-accredited, NIST-traceable included

Add to Compare

Fluke 1551A-12 Calibration Stik Thermometer

1551A Calibration Stik Thermometer, Accurate and repeatable ±0.05°C over its full range with stainless steel probe. The 1551A "Stik" Thermometer is the new "Gold Standard" of industrial temperature calibration. Whether working outdoors in environments where potentially explosive gases may be present or on the floor of processing plant, the intrinsically-safe, battery operated, portable reference thermometer is designed to go where you work.

Features

  • Accuracy of ± 0.05°C over full range
  • Intrinsically safe (ATEX and IECEx compliant)
  • User-configurable Temperature Trend/Stability indicator
  • Display temperature in °C or °F
  • 300-hour battery life
  • Percent battery-life and low-battery indicator
  • NVLAP-accredited, NIST-traceable calibration included

SPECIFICATION

Sensor type 100Ω thin-film RTD
Range -50 to 160°C
Resolution Selectable: 0.1, 0.01, 0.001 (default 0.01)
Accuracy ±0.05°C
Sample rate Selectable: 0.5 second, 1 second, 2 seconds (default 1 second)
Response time ø6.35mm probe : 21 seconds
Probe temperature coefficient 0.00385 Ω/ Ω/ °C nominal
Probe hysteresis ±0.01°C
Communications RS-232 stereo jack (access calibration parameters only)
Sensor length ≤ 10mm
Sensor position (from sheath tip) 3 mm
Minimum immersion depth 70 mm
Probe sheath material Stainless steel
Probe length 305 mm
Power requirement Battery AAA x 3
Dimension / Weight 114 x 57 x 25mm / 196g
SKUFLUKE-1551A-12
Weight196.000000
Dimension114 x 57 x 25mm
ManufacturerFluke
Measurement objectAmbient Temperature, Temperature in Liquid
Sensor connector typeNo
Supported sensor TypeNo
Other Function
  • Display temperature in °C or °F
  • User-configurable temperature Trend/Stability indicator
  • Percent battery-life and low-battery indicator
  • The large backlit LCD display rotates 90° degrees
Power SupplyBattery AAA x 3
Resolution0.1, 0.01, 0.001 (default 0.01)
Temperature Sensor TypeRTD (Pt100, Pt1000)
Number of ChannelNo
Water resistanceNo
Sensor Output InterfaceRS-232
Temperature Range-50 to 160ºC
Data loggerNo
Accuracy±0.05°C
Your Rating

Accessories Included:

  • 1551A-12
  • NVLAP-accredited report of calibration
  • User's Guide on CD-ROM
  • Battery AAA x 3