Fluke-430-II Series Three-Phase Power Quality and Energy Analyzer

SKU
Fluke 430 II Series
Pre-Order Item
In stock

Fluke-430-II Series Three-Phase Power Quality and Energy Analyzer
Quickly see how much money you’re losing due to energy waste in terms of real dollars
Get at-a-glance power quality health data in real-time so you can make better maintenance decisions
Measure all three phases and neutral with the included flexible current probes
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance
Fluke Connect® compatible – view data locally on the instrument,
via Fluke Connect mobile app and PowerLog 430-II desktop software Top Related Products
FLUKE, United States

Product Name Qty
FLUKE-434-II Three-Phase Power Quality and Energy Analyzer Pre-Order Item
FLUKE-435-II Three-Phase Power Quality and Energy Analyzer Pre-Order Item
FLUKE-437-II Three-Phase Power Quality and Energy Analyzer Pre-Order Item
Add to Compare

Fluke-430-II Series Three-Phase Power Quality and Energy Analyzer

As energy saving equipment becomes more and more prevalent in facilities the need to discover where energy is being wasted is becoming more and more important. At the same time these pieces of energy saving equipment like motor drives and electronic lighting have the potential to disrupt the electrical system due to power quality problems. With the Fluke 434 Series II Energy Analyzer you can find out the cost of energy waste due to poor power quality in terms of real dollars lost. You’ll also have the built-in capabilities for characterizing power quality, conducting load studies and capturing hard-to-find voltage events.

With its energy logging capabilities and the Energy Loss Calculator function, the 434 II measures the cost of energy wasted due to poor power quality issues in real dollars. Add basic power quality measurements to the package and you’ve got yourself one powerful troubleshooting tool.

ลักษณะการใช้งานเครื่องวิเคราะห์ไฟฟ้าแบบ 3-Phase

FLUKE-434-II เครื่องวิเคราะห์ไฟฟ้า FLUKE-434-II เครื่องวิเคราะห์ไฟฟ้า FLUKE-434-II เครื่องวิเคราะห์ไฟฟ้า FLUKE-434-II เครื่องวิเคราะห์ไฟฟ้า 

 

Specification Fluke-430-II Series Three-Phase Power Quality and Energy Analyzer

 

เครื่องวิเคราะห์พลังงาน เครื่องวิเคราะห์พลังงาน เครื่องวิเคราะห์พลังงาน

FLUKE-434-II

FLUKE-435-II

FLUKE-437-II

Volt
Measurement Range Vrms (ac+dc) 1 V to 1000 V phase to neutral 1 V to 1000 V phase to neutral 1 V to 1000 V phase to neutral
Resolution Vrms (ac+dc) 0.1 V 0.01 V 0.01 V
Accuracy Vrms (ac+dc) ± 0.5 % of nominal voltage**** ± 0.1 % of nominal voltage**** ± 0.5 % of nominal voltage****
Amps  (accuracy excluding clamp accuracy)
Measurement Range (i430-Flex 1x) 5 A to 6000 A 5 A to 6000 A 5 A to 6000 A
Resolution  (i430-Flex 1x) 1 A 1 A 1 A
Accuracy  (i430-Flex 1x) ±0.5% ±5 counts ±0.5% ±5 counts ±0.5% ±5 counts
Hz @ 50 Hz nominal
Measurement Range 42.50 Hz to 57.50 Hz 42.50 Hz to 57.50 Hz 51.000 Hz to 69.000 Hz
Resolution  0.01 Hz 0.01 Hz 0.001 Hz
Accuracy  ±0.01 Hz ±0.01 Hz ±0.01 Hz
Hz @ 60 Hz nominal
Measurement Range 51.000 Hz to 69.000 Hz 51.000 Hz to 69.000 Hz 51.000 Hz to 69.000 Hz0 Hz
Resolution  0.01 Hz 0.01 Hz 0.001 Hz
Accuracy  ±0.01 Hz ±0.01 Hz ±0.01 Hz
Hz @ 400 Hz nominal
Measurement Range - - 340.0 Hz to 460.0 Hz
Resolution  - - 0.1 Hz
Accuracy  - - ±0.1 Hz
SD Card 8 GB 8 GB 8 GB
Power
Measurement Range max 6000 MW max 6000 MW max 6000 MW
Resolution  0.1 W to 1 MW 0.1 W to 1 MW 0.1 W to 1 MW
Accuracy  ± 1 % ± 10 counts ± 1 % ± 10 counts ± 1 % ± 10 counts
Energy
Measurement Range Depends on clamp scaling and V nominal Depends on clamp scaling and V nominal Depends on clamp scaling and V nominal
Resolution  Depends on clamp scaling and V nominal Depends on clamp scaling and V nominal Depends on clamp scaling and V nominal
Accuracy  ± 1 % ± 10 counts ± 1 % ± 10 counts ± 1 % ± 10 counts
Harmonics Order (n)
  DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7

****for nominal voltage 50 V to 500 V

 

Function Fluke-430-II Series Three-Phase Power Quality and Energy Analyzer

FLUKE-434-II FLUKE-435-II FLUKE-437-II
Energy Monetization Frontline Troubleshooting Frontline Troubleshooting ( to 400 Hz.)
Energy Assessment Long-Term Analysis Long-Term Analysis ( to 400 Hz.)
Frontline Troubleshooting Load Studies Load Studies ( to 400 Hz.)
Predictive Maintenance PowerWave Data Capture PowerWave Data Capture ( to 400 Hz.)
Long-Term Analysis Power Inverter Efficiency Power Inverter Efficiency ( to 400 Hz.)
Load Studies Energy Monetization Energy Monetization ( to 400 Hz.)
- Energy Assessment Energy Assessment ( to 400 Hz.)
- Predictive Maintenance Predictive Maintenance

 

Industrial and commercial building applications

A Frontline troubleshooting and predictive maintenance
B Load studies
C Energy surveys
D Voltage quality
E Long-term and intermittent analysis

 

SKUFluke 430 II Series
ManufacturerFluke
Data loggerYes
Resolution 0.1 V
Measurement Range1 V to 1000 V phase to neutral
Other FunctionNo
Power SupplyBC430 Power Adapter
Water resistanceNo
Sensor Output InterfaceNo
Accuracy±0.5% of nominal voltage
Your Rating