GW Instek LCR-6002 Benchtop LCR Meters
The LCR-6002 with a test frequency range 10Hz ~ 2kHz and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The LCR-6002 with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc.
The LCR-6002 provides rich functionalities with the compact size. First of all, the entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.
Consecutive frequency and Convenient zero function
The LCR-6002 within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. The LCR-6002 is equipped with full frequency range zero and spot zero selections.
|
|
Consecutive and adjustable frequency Freely input frequency within provided frequency range |
Selectable fixture zeroing methods Full frequency range zero or spot zero |
Rich and diverse information display
The measurement result display of the LCR-6002 not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. The LCR-6002 features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results.
|
|
MEAS displayParameter setting and four measurement parameters |
ENLARGE displayEnlarge measurement results and include PASS/FAIL judgment |
10 points listed tests and PC software
The LCR-6002 provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. In addition to provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation.
|
|
Listed tests Variation criteria based upon frequency or voltage/current |
On software ─ characteristic curve Provide more delicate characteristic variation trend |
Diverse ancillary measurement functions
To satisfy the diverse measurement application requirements for different components and materials, the LCR-6002 collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation.
|
|
Automatic level control Ideal for measuring components with voltage requirements |
Internal bias (±2.5V adjustable) Provide more delicate characteristic variation trend |
Standard Interface
For interface connectivity, the LCR-6002 comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications.
|
Standard interface RS-232C (left), Handler (right) |
TEST FREQUENCY |
|
10Hz~ 2kHz(±0.01%) (4 digits resolution) |
OUTPUT IMPEDANCE |
|
30Ω / 50Ω / 100Ω selectable |
BASIC ACCURACY |
Slow / Med |
0.05% |
Fast |
0.1% |
TEST SPEED |
|
FAST:25ms / MED:100ms / SLOW:333ms |
TEST SIGNAL LEVELS |
AC Voltage |
10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%) |
AC Current |
100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax) |
DCR |
±1V(2Vpp), Square wave, 3Hz up 0.033A(Max) |
DC BIAS |
Internal |
±2.5V (0.5%+0.005V) |
DISPLAYRANGE |
R, X, |Z| |
0.00001Ω ~ 99.9999MΩ |
G, B, |Y| |
0.01nS ~ 999.999S |
L |
0.00001uH ~ 9999.99H |
C |
0.00001pF ~ 9999.99mF |
D |
0.00001 ~ 9.99999 |
Q |
0.00001 ~ 99999.9 |
θd |
-179.999° ~ 179.999° |
θr |
-3.14159 ~ 3.14159 |
DCR |
0.00001Ω ~ 99.9999MΩ |
Δ% |
-99999% ~ 99999% |
TEST MODE |
16 Combinations |
Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR |
Monitor parameter (2 selectable) |
Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y |
LISTED MODE |
|
10 steps |
BIN FUNCTION |
|
Comparator (9BIN,AUX:1BIN) |
MEMORY |
INT – panel setting |
10 file name |
INT – measured data |
10000 Data(.csv) |
USB storage |
10 file name for setting, 9999 file name for data, 999 Log file for LCD screen |
OTHER FUNCTION |
Auto Level Control (ALC) |
ON/OFF |
Average |
1~256 times |
Trigger |
INT / MAN / EXT / BUS |
Delay |
0ms~60s |
Judgment |
PASS / FAIL |
Auto LCZ |
ON/OFF |
Screen Capture |
Saving in to USB (Bmp form) |
DISPLAY |
|
3.5'LCD, RGB color (320x240) |
INTERFACE |
|
RS-232(SCPI), Handler, USB Host |
POWER SOURCE |
|
AC 90V-250V, 50-60Hz, Max. 30VA |
DIMENSIONS & WEIGHT |
|
265(W)x107(H)x312(D) mm, Approx.3kg |