GW Instek LCR-6002 Benchtop LCR Meters

SKU
LCR-6002
Out of stock

3.5” color LCD
Consecutive test frequency: 10Hz ~ 2kHz
Measuring speed up to 25ms (max.)
Basic accuracy : 0.05%
DCR measurement and internal D.C. bias voltage (±2.5V)
USB Host For Data Storage and Display Screen Retrieval
Corresponding Functional Keys Provide More Intuitive And Fast Operation
maximum four different parameters can be shown simultaneously
Auto Level Control (ALC) function

GW Instek LCR-6002 Benchtop LCR Meters

The LCR-6002 with a test frequency range 10Hz ~ 2kHz and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The LCR-6002 with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc.

The LCR-6002 provides rich functionalities with the compact size. First of all, the entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.

Consecutive frequency and Convenient zero function

The LCR-6002 within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. The LCR-6002 is equipped with full frequency range zero and spot zero selections.

Digital Image Thermal Image
Consecutive and adjustable frequency
Freely input frequency within provided frequency range
Selectable fixture zeroing methods
Full frequency range zero or spot zero


Rich and diverse information display

The measurement result display of the LCR-6002 not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. The LCR-6002 features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results.

Digital Image Thermal Image
MEAS displayParameter setting and four measurement parameters ENLARGE displayEnlarge measurement results and include PASS/FAIL judgment

10 points listed tests and PC software

The LCR-6002 provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. In addition to provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation.

 Digital Image  Thermal Image
 Listed tests
Variation criteria based upon frequency or voltage/current
 On software ─ characteristic curve
Provide more delicate characteristic variation trend

Diverse ancillary measurement functions

To satisfy the diverse measurement application requirements for different components and materials, the LCR-6002 collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation.

Digital Image Thermal Image
Automatic level control
Ideal for measuring components with voltage requirements
Internal bias (±2.5V adjustable)
Provide more delicate characteristic variation trend

Standard Interface

For interface connectivity, the LCR-6002 comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications.

Digital Image
Standard interface
RS-232C (left), Handler (right)
TEST FREQUENCY
  10Hz~ 2kHz(±0.01%) (4 digits resolution)
OUTPUT IMPEDANCE
  30Ω / 50Ω / 100Ω selectable
BASIC ACCURACY
Slow / Med 0.05%
Fast 0.1%
TEST SPEED
  FAST:25ms / MED:100ms / SLOW:333ms
TEST SIGNAL LEVELS
AC Voltage 10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%)
AC Current 100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax)
DCR ±1V(2Vpp), Square wave, 3Hz up 0.033A(Max)
DC BIAS
Internal ±2.5V (0.5%+0.005V)
DISPLAYRANGE
R, X, |Z| 0.00001Ω ~ 99.9999MΩ
G, B, |Y| 0.01nS ~ 999.999S
L 0.00001uH ~ 9999.99H
C 0.00001pF ~ 9999.99mF
D 0.00001 ~ 9.99999
Q 0.00001 ~ 99999.9
θd -179.999° ~ 179.999°
θr -3.14159 ~ 3.14159
DCR 0.00001Ω ~ 99.9999MΩ
Δ% -99999% ~ 99999%
TEST MODE
16 Combinations Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q,
Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR
Monitor parameter (2 selectable) Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y
LISTED MODE
  10 steps
BIN FUNCTION
  Comparator (9BIN,AUX:1BIN)
MEMORY
INT – panel setting 10 file name
INT – measured data 10000 Data(.csv)
USB storage 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen
OTHER FUNCTION
Auto Level Control (ALC) ON/OFF
Average 1~256 times
Trigger INT / MAN / EXT / BUS
Delay 0ms~60s
Judgment PASS / FAIL
Auto LCZ ON/OFF
Screen Capture Saving in to USB (Bmp form)
DISPLAY
  3.5'LCD, RGB color (320x240)
INTERFACE
  RS-232(SCPI), Handler, USB Host
POWER SOURCE
  AC 90V-250V, 50-60Hz, Max. 30VA
DIMENSIONS & WEIGHT
  265(W)x107(H)x312(D) mm, Approx.3kg
SKULCR-6002
Weight3000.000000
Dimension265(W)x107(H)x312(D) mm
ManufacturerGW_Instek
Data loggerYes
Resolution 4 digits resolution
Measurement RangeR, X, |Z| : 0.00001Ω ~ 99.9999MΩ
G, B, |Y| : 0.01nS ~ 999.999S
L: 0.00001uH ~ 9999.99H
C: 0.00001pF ~ 9999.99mF
D: 0.00001 ~ 9.99999
Q: 0.00001 ~ 99999.9
θd: -179.999° ~ 179.999°
θr: -3.14159 ~ 3.14159
DCR: 0.00001Ω ~ 99.9999MΩ
Δ% : -99999% ~ 99999%
Other Function

Auto Level Control (ALC) : ON/OFF
Average: 1~256 times
Trigger: INT / MAN / EXT / BUS
Delay: 0ms~60s
Judgment: PASS / FAIL
Auto LCZ: ON / OFF
Screen Capture: Saving in to USB (Bmp form)

Power SupplyAC 90V-250V, 50-60Hz, Max. 30VA
Water resistanceNo
Sensor Output InterfaceUSB Host, RS-232C interface, Handler outputs 10 BIN (9BIN, AUX: 1BIN)
AccuracySlow / Med : 0.05% Fast : 0.1%
Your Rating

Accessories Include

Safety Sheet x 1
Power Cord x 1
Test Fixture LCR-06Ax 1
CD x1(User manual / PC software)

Optional Accessories

LCR-05, Test Fixture for Axial & Radial Lead Components
LCR-06B, Kelvin Clip Test Lead
LCR-07, Test Fixture, Two-Wire with Alligator Clips
LCR-08, Test Fixture (Tweezers) for SMD/Chip Components
LCR-15, Test Fixture for SMD/Chip Components (0201 to 1812)
LCR-16, Test Fixture – ±45V DC Bias Voltage Box
LCR-17, Test Fixture – ±2.5ADC Bias Current Box
GTL-232, RS-232C Cable, 9-pin Female to 9-pin, null Modem for Computer, Approx.2m