Hioki 3286-20 Power Clamp Meter (AC clamp on power), true RMS

SKU
HIOKI-3286-20
Out of stock

- Single-phase, Three-phase measurement line
- Voltage, Current, Voltage/current peak, Active/ reactive/ apparent power, Power factor, Phase angle, Reactivity, Frequency, Voltage/current harmonic levels
- Voltage range: 600 V. (max.), Current range: 1000 A. (max.), True RMS value
- Single phase 3-600 kW., 3 phase (balanced, no distorted) 6-1200 kW.
- Hioki, Japan

** Discontinued Product **

Hioki 3286-20 แคลมป์วัดกำลังไฟฟ้า (AC, true RMS)


Measurement line

- Single-phase
- Three-phase (balanced with no distortion)

Voltage ranges 30 - 1kHz
- Measurement range: 150.0 V to 600 V, 3 ranges
- Accuracy ±1.0 % rdg (at 45 - 66 Hz, True RMS)

Current ranges 45 - 1kHz
- Measurement range: 20.00 A to 1000 A, 3 ranges
- Accuracy: ±1.3 % rdg (at 45 - 66 Hz, True RMS)

Power ranges 80 - 600 V, 1 - 1000 A
- Single phase measurement range: 3.000 kW to 600.0 kW
 -Accuracy: ±2.3 % rdg (at 50/60 Hz, Power factor = 1)
- Three phase measurement range: 6.000 kW to 1200 kW
- Accuracy: ±3.0 % rdg(at 50/60 Hz, Power factor = 1)

Harmonic level
- Voltage/current harmonic levels up to 20th, Content factor, Total harmonic distortion ratio

Other function
- Phase angle Forward 90° to 0 to delay 90°
- Power factor Forward 0 to 1.000 to delay 0
- Frequency 30.0 Hz to 1000 Hz
- Waveform peak, phase detection, max/min record, data hold, auto power off 

Display: LCD Screen, 6000 digit
CATIII 600V
Power supply: Alkaline battery 9V (6LR61, 6LF22) x 1, Continuous use: 25 hours (using 6LR61)
size: 100 x 287 x 39mm (650g), Core jaw diameter: 55 mm. or 80 x 20 mm. bus-bar
Accessories: Hioki 3286-20 x 1, Voltage Cord 9635-01 x 1, Hand strap x 1 , Alkaline battery (6LR61) 9V x 1, Carrying case 9245 x 1 , Instruction manual x 1
Manufacturer: Hioki, Japan

คลิกที่นี่เพื่ออ่านบทความ แคลมป์มิเตอร์ จาก Hioki

คลิกที่นี่เพื่อรับชมสินค้า แคลมป์มิเตอร์ประเภทอื่นๆจาก Hioki



SKUHIOKI-3286-20
Weight650.000000
Dimension100 x 287 x 39mm
ManufacturerHioki
Data loggerNo
Resolution No
Measurement Range

Voltage ranges 30 - 1kHz
- Measurement range: 150.0 V to 600 V, 3 ranges
- Accuracy ±1.0 % rdg (at 45 - 66 Hz, True RMS)

Current ranges 45 - 1kHz
- Measurement range: 20.00 A to 1000 A, 3 ranges
- Accuracy: ±1.3 % rdg (at 45 - 66 Hz, True RMS)

Power ranges 80 - 600 V, 1 - 1000 A
- Single phase measurement range: 3.000 kW to 600.0 kW
 -Accuracy: ±2.3 % rdg (at 50/60 Hz, Power factor = 1)
- Three phase measurement range: 6.000 kW to 1200 kW
- Accuracy: ±3.0 % rdg(at 50/60 Hz, Power factor = 1)

Other Function

Harmonic level
- Voltage/current harmonic levels up to 20th, Content factor, Total harmonic distortion ratio

Other function
- Phase angle Forward 90° to 0 to delay 90°
- Power factor Forward 0 to 1.000 to delay 0
- Frequency 30.0 Hz to 1000 Hz
- Waveform peak, phase detection, max/min record, data hold, auto power off 

Power SupplyAlkaline battery 9V (6LR61, 6LF22) x 1
Water resistanceNo
Sensor Output InterfaceRS232C Interface
Accuracy

Voltage ranges 30 - 1kHz
- Accuracy ±1.0 % rdg (at 45 - 66 Hz, True RMS)

Current ranges 45 - 1kHz
- Accuracy: ±1.3 % rdg (at 45 - 66 Hz, True RMS)

Power ranges 80 - 600 V, 1 - 1000 A
- Single phase accuracy: ±2.3 % rdg (at 50/60 Hz, Power factor = 1)
- Three phase accuracy: ±3.0 % rdg(at 50/60 Hz, Power factor = 1)

Your Rating

Accessories

Hioki 3286-20 x 1
Voltage Cord 9635-01 x 1
Hand strap x 1 
Alkaline battery (6LR61) 9V x 1
Carrying case 9245 x 1 
Instruction manual x 1